Flame Photometers from Kruess Optronics

Flame Photometer FP8000 Series

The KR√úSS flame photometers allow simple and cost-effective determination of alkali and alkaline earth element concentrations in aqueous solutions. They are mainly used in laboratory and process operations. The FP8000 series presents unique measuring devices for simultaneous measurement of the elements Na, K, Ca and Li. Five measurement channels are available to be individually configured. Thanks to the proven measurement procedure as well as to modern device electronics and innovative process control, our flame photometers achieve highly accurate and reproducible results. The devices can cope with about 300 measurements per hour.

FP8400 Standard version for Laboratory. Economic entry level solution. CALIBRATION Linear with 2 standards. Non linear with 6-8 standards, cubic approximation. REFERENCE Lithium guide line with 5 mmol/l. SAMPLE VOLUME 2.5 ml . COMBUSTION GAS Propane: recommended for alkaline elements. Acetylene for flame photometry: recommended for alkaline earth elements. DISPLAY TFT-Display with integrated 8,4“ TFT touchscreen, 800x600 Pixel
INTERFACES 2 x USB flash drive 1 x Ethernet 1 x RS-232 for printer
ACCESSORIES 24 character plain paper printer
Pressure reducing station with filter unit. Various standards and system solutions

 

 

 

FP8500 Version for Process Remote control of multiple devices via centre process computer. CALIBRATION Linear with 2 standards Non linear with 6-8 standards, cubic approximation REFERENCE Lithium guide line with 5 mmol/l SAMPLE VOLUME 2.5 ml COMBUSTION GAS Propane: recommended for alkaline elements Acetylene for flame photometry: recommended for alkaline earth elements DISPLAY TFT-Display with integrated 8,4“ TFT touchscreen, 800x600 Pixel
INTERFACES 2 x USB flash drive 1 x Ethernet 1 x RS-232 for printer Upgrade 4-20 m Aanalog, passive current interface
ACCESSORIES 24 character plain paper printer Pressure reducing station with filter unit Various standards and system solutions

 

 

 

FP8600 Version with Sampler, external sample table and control unit Automated procedures for operation with high sample throughput Samples are measured undiluted. High precision. CALIBRATION Linear with 2 standards. Non linear with 6-8 standards, cubic approximation. REFERENCE Lithium guide line with 5 mmol/l. SAMPLE VOLUME 2.5 ml . COMBUSTION GAS Propane: recommended for alkaline elements. Acetylene for flame photometry: recommended for alkaline earth elements. DISPLAY TFT-Display with integrated 8,4“ TFT touchscreen, 800x600 Pixel
INTERFACES 2 x USB flash drive 1 x Ethernet 1 x RS-232 for printer
ACCESSORIES 24 character plain paper printer
Pressure reducing station with filter unit. Various standards and system solutions

 

 

FP8700 External automation system consisting of: sampler, diluter and mixer Automated procedures for operation with high sample throughput Samples are measured diluted. High precision. Small amount of sample.CALIBRATION Linear with 2 standards. Non linear with 6-8 standards, cubic approximation. REFERENCE Lithium guide line with 5 mmol/l. SAMPLE VOLUME 0.25 ml . COMBUSTION GAS Propane: recommended for alkaline elements. Acetylene for flame photometry: recommended for alkaline earth elements. DISPLAY TFT-Display with integrated 8,4“ TFT touchscreen, 800x600 Pixel
INTERFACES 2 x USB flash drive 1 x Ethernet 1 x RS-232 for printer
ACCESSORIES 24 character plain paper printer
Pressure reducing station with filter unit. Various standards and system solutions

 

Flame Photometer Accessories Includes calibration standards, auto sampler and diluter

Technical Data ppm

 

Technical Data mmol/liter