Flow Meters, Flow Meters with Magnetic Floats and with Limit Switches

Variable Area Flow Meters. Ideal for plastic piping systems, they provide a combination of accurate flow measurement and clear flow indication from a distance. The units must be installed vertically with the flow upwards. Tube materials are available in clear PVC, Polyamide(PA), Polysulfone(PSU) and PVDF. The flow meters are accurate to ±3% of indicated value and ±1% of full scale

. Optional limit switches allow the units to signal a low or high flow alarm.

flow metersCompact Variable Area Flow Meters, 3/8" to 1/2"
Compact Variable Area Flow Meters 3/4" to 1"
Full Size Variable Area Flow Meters, 1" to 1-1/4"
Full Size Variable Area Flow Meters, 1-1/2" to 2-1/2"

 

For Variable Area Flow Meters

Variable area Flow Meters with Magnetic Floats.

An optional flow transmitter provides a 4 to 20 mA signal output. These flow meters must be installed vertically with flow upward.

flow meters with magnetic floatsCompact Flow Meters, 3/8in to 1/2 in with Magnetic Floats
Compact Flow Meters 3/4in & 1in with Magnetic Floats
Full Size Flow Meters 1" to 1-1/4in with Magnetic Floats
Full Size Flow Meters, 1-1/2in to 2-1/2in with Magnetic Floats

 

Variable Area Flow Meters with Magnetic Float and Limit Switch

The LSFLO limit switches serve as switches for minimum or maximum flow values. The normally open latching reed switch closes when the float in the measuring tube reaches and exceedes the switching position. The switch condition is maintained as long as the float is above the limit switch and will open when the float in the tube drops below the switch.
Normally closed switches are available on request.

Compact Size Flowmeter complete with Magnetic Float and (1) LSFLO Limit switch. 3/8in to 1in
Full Size Flowmeter complete with Magnetic Float and (1) LSFLO Limit switch. 1in to 2-1/2in

For Flow Meters with Magnetic Floats and Limit Switch

 

ZE3000 Flow Transmitters for FS Flow Meters

The ZE3000 flow transmitter provides a 4–20 mA output signal, generated by detection of the position of the magnetic float.
IMPORTANT: This micro-processor controlled unit is factory calibrated and unique to each flowmeter model. Flowmeter model must be advised when ordering.

 

ZE3075 Flow Transmitters

The ZE3075 flow transmitter provides a 2- wire 4–20 mA output signal omit generated by precise detection of the position of the magnetic float.
The magnetic float travels along the reed chain of switches activating them.This micro-processor controlled unit is field calibrated.